Lodestar FM-CS2
office@a3.energy
+7 499 450-55-07
arabic language

Lodestar FM-CS2

Lodestar FM
Description

Minimum dimensions – maximum functionality.

А Feeder Monitor Lodestar FM-CS2 can be used as a logger, fault current indicator, high-voltage control device. It is designed for switchgear cell with double cable output.

Lodestar FM-CS2:

  • Detects fault direction
  • Effective in resonant grounded neutral grid
  • Logs all types of emergency situation:
    - phase-to-phase faults;
    - phase -to-ground faults;
    - 2-or-3-phase -to-ground faults
  • Operates in mixed networks: overhead, cable and overhead-cable ones
  • High accuracy in measurement of current and voltage
  • Up to 0.1 A short-circuit faults logging
  • Immediate data processing in the Device
  • Operates in double-ended and loop fed networks, as well as in radial networks
  • Feeder Monitor Lodestar FM-CS2 displays a faulted phase on the front LED-display
  • Event information both visually and in the SCADA system
  • Easy to configure by a couple of clocks in SW
  • Memorizes more than 200 events

Combines the functions of selective detection of all faulted lines and main power parameters measurement.

Feeder Monitor Lodestar FM-CS2 monitors independently each input of switchgear cell with double cable input The Device in mounted in a switchgear cell or on a switchboard.

Technical characteristics of Lodestar FM-CS2

Parameters Values
 Types of logged faults - 2-and-3- phase short-circuit fault identification;
- 2-and-3- phase short-circuit fault direction finding;
- 2-and-3- phase-to-ground fault identification;
- 2-and-3- phase-to-ground fault direction finding;
- Phase-to-ground fault identification;
- Phase-to-ground fault direction finding.
 Recording the line switching faults  Yes
 Selictivity  Phase-to-ground and short-circuit faults direction finding
 Minimum zero sequence current for phase-to-ground fault logging  0.5 А
 Fault visual indication − LED-display;
− LED-indication
 Number of memorized faults  240
 Power supply used in the indicator - Inbuilt standby removable lithium storage battery (15 years);
- Powered via operation current source with any type of voltage =100 – 240 V (±10%),
 Fault indication reset - By an external command;
- By the timer;
- By the device button
 Interface RS-485 MODBUS communication protocol
Ethernet IEC104 communication protocol
 Logging of  - Voltage;
- Current;
- Power;
- Industrial frequency;
- Power factor in three phases;
- Flow distribution direction
 Measurement accuracy - Voltage:
  - when using capacitive dividers - 3%;
  - when using voltage transformer - 1%;
- Current 3%;
- Active, reactive and full power - 3%;
- Industrial frequency - 1%
Temperature Range standard from -50 ° С to +70 ° С